Software, IT, OT & cybersecurity

TwinCAT Controller Redundancy: redundant control with standard hardware components

TwinCAT Controller Redundancy beschermt de uptime van de installatie door redundante besturing met behulp van standaardcomponenten.
TwinCAT Controller Redundancy beschermt de uptime van de installatie door redundante besturing met behulp van standaardcomponenten.

Plant availability is particularly critical in the process industry, making redundancy in automation technology essential. Beckhoff has therefore expanded its extensive range of solutions in this area with a software solution for redundant control: TwinCAT Controller Redundancy.

Software-based solution protects plant uptime through redundant control

Although the robust design of the company’s industrial PCs already ensures a high level of availability, Beckhoff is now expanding its product portfolio further with TwinCAT Controller Redundancy (TF1100). This fully software-based solution enables two standard industrial PCs, both running the same PLC program, to operate as redundant controllers in just a few simple steps. 

An additional high-performance network connection between the two controllers provides the necessary synchronisation. Standard Ethernet is used, so no dedicated hardware components are required. With minimal effort, this ensures that only one of the two industrial PCs at a time communicates with the fieldbus components, while the control programs run simultaneously on both computers. This synchronisation is essential to ensure that, in the event of a fault, the primary industrial PC can be replaced without any loss of information. 

Other redundancy methods

In addition to controller redundancy, the proven EtherCAT Redundancy software (TF6220) protects against faults caused by defective cable connections. The I/O modules are connected by two separate cables, ideally installed via different routes. While EtherCAT Redundancy handles communication between the controller and the fieldbus, TwinCAT Parallel Redundancy Protocol (PRP, TF6230) now also provides cable redundancy for Ethernet communication in accordance with IEC 62439-3 to higher-level systems such as MES or standalone HMI systems. The protocol defines a redundant and transparent network connection that can be monitored and diagnosed in TwinCAT. 

Een zakelijke vraag aan Beckhoff Automation? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeFrom design to flexible machine
  • SubjectSoftware, IT, OT & cybersecurity
  • CompanyBeckhoff Automation
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.