Software, IT, OT & cybersecurity

IO-Link supports predictive maintenance strategies with flexibility in the Industrie 4.0 era

IO-Link supports predictive maintenance strategies with flexibility in the Industrie 4.0 era

Smart manufacturing minimises downtime and optimises efficiency

As Industrie 4.0 moves from concept to implementation, factory and production equipment is using industrial networks to become more connected and intelligent. This is driven primarily by the need for improved performance, efficiency and productivity. When choosing a communication protocol, both from a hardware and software perspective, factors such as redundancy, flexibility and scalability, and ease of implementation also need to be considered.

Crucially, adding intelligence to machines also makes it possible to implement a predictive maintenance strategy. Being able to anticipate problems and plan ahead, rather than reacting to maintenance needs, minimises downtime and the associated costs, which is extremely valuable to users.

Smarter manufacturing with a predictive maintenance strategy can only be achieved by collecting a substantial amount of real-time sensor data. A versatile product line, a key benefit of smart manufacturing for businesses producing a range of products, needs data to make decisions about adapting and adjusting production lines.

IO-Link stands out from the crowd
IO-Link, also known as SDCI (Single-Drop Digital Communication), is an open communication protocol that emerged from a host of cost-saving alternatives that had been around for some time. What sets it apart is that it is a powerful protocol well suited to Industrie 4.0. In simple terms, it enables straightforward, scalable, point-to-point communication between sensors or actuators and the controller. Essentially, it is like an industrial USB. Parker Hannifin is one of more than 130 companies in the IO-Link community, which has now achieved more than 3.5 million nodes in the field. This level of market penetration demonstrates not only the protocol’s relevance to market needs, but also its reliability.

Automated factory environments typically include large control cabinets containing PLCs, I/O cards and terminals. These provide the interface for all machine-to-machine communication. With IO-Link’s cost-effective IP67 master blocks, many of these elements can be located directly on the machine, significantly reducing cabinet space. This is achieved by bringing the IO-Link master closer to the point of detection, simplifying communication and cabling. This is considerably more cost-effective than using IP67 Ethernet blocks for on-machine I/O. Compared with discrete wiring, IO-Link significantly reduces the amount of wiring required between manifolds and sensors, as well as the number of connections. This in turn improves overall reliability, since every connection is a potential point of failure or system downtime. In addition, the standard unshielded M12 cables and connectors used in IO-Link have just three or five wires and offer many design, implementation and reliability benefits compared with the traditional 25-pin and D-sub connectors often used in machine and production automation and control systems.

IO-Link and predictive maintenance
Current trends are increasingly shifting towards predictive and preventive, rather than reactive, maintenance. Predictive maintenance is widely recognised as the way to go, not only in industrial automation but across many industries. A study by Accenture and GE found that predictive maintenance can reduce maintenance costs by 30% and cut production downtime caused by equipment failure by up to 70%. IO-Link is particularly well suited to this approach and philosophy. 

Installation
While the main benefits of reduced costs and downtime accrue over the long life of the production process and system, IO-Link also offers significant advantages during installation. Thanks to its simpler point-to-point topology, IO-Link is quicker and easier to install than other control and regulation methods, such as Ethernet. It enables rapid troubleshooting during commissioning, which can be carried out locally or remotely. False sensor settings and other bottlenecks are also much easier to detect, isolate and resolve. Compared with a decentralised model, IO-Link’s centralised model also offers cost benefits, both in the actual cost of the required hardware and in the labour costs of installing and connecting it.

In operation
IO-Link delivers its greatest and most consistent benefits throughout the normal operating life of an installation. With multiple, easily expandable measurement points, IO-Link provides extensive, accurate data points across the machine and communicates them in real time, allowing processes to be monitored closely.

Sensor-detected movements outside adjustable preset parameters trigger alarms and can be addressed quickly, before costly unplanned production interruptions or product damage occur. In many cases, early notification of problems by sensors enables system managers to investigate, assess and schedule the necessary corrective maintenance for a period when production capacity is low or production can be stopped. This could be overnight or during a longer planned shutdown of the installation. The cost and disruption caused by unavoidable downtime are reduced, and replacement parts can be procured and repairs carried out with the greatest possible control and efficiency.

Flexibility and robustness
Thanks to its decentralised, plug-and-play topology, IO-Link is flexible. This flexibility is further enhanced by modules and devices from different suppliers that can be combined with ease. This makes it possible to extend or adapt existing implementations by adding more sensors and actuators for improved diagnostics, monitoring and control. This means that production environments can be reconfigured quickly and easily, with low risk compared with more complex, industrial Ethernet approaches tied to specific vendors.

Not all production environments are clean, dry and free from vibration and/or other environmental factors, which can compromise the reliability of communication networks installed to detect, monitor and/or control processes. This is particularly true when there are many connections, each of which is a potential point of failure. The standard unshielded five-pin cables and proximity switch connectors used in IO-Link are designed specifically for industrial applications. They are robust and have an IP65 or IP67 rating, demonstrating their resistance to the challenges of most operating environments. Since all IO-Link data transmission is based on a 24-volt signal, susceptibility to electrical interference is not an issue, and shielded cables or other forms of grounding are not required.

Conclusion
With the widespread adoption of smart factories becoming increasingly inevitable, it is important to have a dedicated communication network that maximises ease of implementation while also offering the versatility to adapt to changing needs and configurations. Moreover, with the benefits of predictive maintenance well understood, many manufacturing organisations are keen to adopt the strategy and reap its rewards. IO-Link is well positioned and equipped to meet these needs. Its inherent robustness and vendor neutrality will make it the industrial communication approach of choice for many sectors.

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeData from shop floor to decision
  • SubjectSoftware, IT, OT & cybersecurity
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.