White paper: Optimise your power supply with condition monitoring

White paper: Optimise your power supply with condition monitoring

Maintaining your electrical installation is crucial. But components are often replaced too soon, or people wait until it is too late. A costly mistake. Condition monitoring keeps you informed about the condition of your electrical components, helping you optimise maintenance and, in turn, cost efficiency.

This white paper uses Siemens 3VA circuit-breakers as an example.

Without power, the lights go out

A reliable power supply is essential for your industrial processes. The fewer interruptions and breakdowns, the higher your productivity and the lower your unit costs. In many sectors, power cuts simply cannot be tolerated. Think of hospitals, data centres, glass factories and more.

That is why all electrical components must function properly at all times. Maintaining and replacing ageing parts is crucial. But if you replace components too soon, you incur unnecessary costs and reduce efficiency. And, of course, you must not wait until it is too late. Condition monitoring offers a smart solution.

Keep your circuit-breakers in check

Circuit-breakers are key components of your power supply. They manage the flow of electricity and protect your electrical infrastructure against short circuits and overloads. Circuit-breakers are subject to wear and tear depending on operating hours, switching cycles, the number of trips …

Until now, service life was estimated based on assumed usage (if it was even known) and catalogue values. In other words, it was largely guesswork. The Siemens 3VA circuit-breaker, by contrast, has a health indicator built in, giving you a more accurate picture of its remaining service life. This lets you plan maintenance and replacement more efficiently, save costs and avoid interruptions.

Siemens 3VA circuit-breaker with condition monitoring

Every 3VA circuit-breaker is equipped with a health indicator. This percentage value is calculated based on an analysis of switching operations and trips, and is updated after every switching cycle. The health indicator is shown on the electric trip unit (ETU) display, and can also be accessed via various applications (e.g. from the SENTRON portfolio).

A patented algorithm calculates the remaining service life of the circuit-breaker based on changes in the health indicator and an analysis of previous operating behaviour. Unexpected trips with high current surges can therefore sharply reduce the remaining service life. And, of course, you can also access this information via user-friendly applications.

Optimised maintenance and replacement

Until now, you had to maintain all your electrical components individually, either at times chosen more or less at random or on an unplanned basis when a problem arose. This led to breakdowns and even unwanted stoppages of industrial operations.

With condition monitoring, as used on 3VA circuit-breakers, you can maintain your electrical installation predictively based on accurate data and optimise your power supply. This helps you get more out of your components and deploy your maintenance staff where they are needed. That saves you time and money. Having continuous access to data from all your components in a secure (cloud) application also makes things much easier. Make the most of today’s smart technology.

Interested in this topic? Get in touch with us.

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeLess downtime through maintenance
  • SubjectServices & solutions
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.