Modbus gateways simplify data communications across a range of applications

The smooth communication between components is one of the factors that determines whether an installation operates effectively. Simplifying this communication often requires data to be converted from one protocol to another. With their rugged industrial design, Moxa’s protocol gateways are ideal tools for achieving this reliably. For example, MGate MB3170 gateways were used to convert Modbus RTU data to Modbus TPC data in data centres, while the MGate 5103 converts Modbus data to Profinet in paper mills. In both applications, Moxa’s products have a positive impact on energy efficiency.

From Modbus RT to TCP
A world-leading computer technology company called on an energy management system (EMS) integrator to develop a solution to optimise energy efficiency in its data centres. This required the collection of data on energy consumption and the temperature of the power distribution units (PDUs), enabling operators to use this information to limit energy losses and ensure suitable power distribution conditions.

“The specialists used Moxa MGate MB3170 Modbus gateways to ensure smooth data communication between the PDUs and the EMS. The gateways seamlessly convert all the Modbus RTU data collected via the power meters and temperature sensors into Modbus TCP data, which can be easily integrated into the Ethernet-based energy management system,” says Karel Mus, managing director of Technolec, which distributes Moxa solutions in Belgium. “These protocol gateways are also ideally suited to bulk configuration by IT engineers, while Ethernet cascading allows them to be deployed flexibly between dozens of PDUs in data centres.”

From Modbus to Profinet
In another application, a system integrator helped a customer implement switchgear in paper mills. To ensure a stable power supply, operators need to control and monitor these systems via a Profinet-based PLC. However, the power meters in the switchgear usually use the Modbus RTU protocol, as this solution is cheaper than Profinet-based power meters. A gateway was needed to convert Modbus to Profinet and simplify data communication.
“Moxa MGate 5103 Modbus-to-Profinet gateways ensure smooth communication between the switchgear and the PLCs. But that’s not all. They feature a serial port with 2 kV isolation protection and meet standard class 3 electromagnetic compatibility (EMC) requirements, ensuring stable operation in environments with strong electromagnetic radiation,” explains Karel Mus. “Moxa’s compact protocol gateways also simplify implementation with a user-friendly web UI that allows users to complete the configuration in just four steps.”
Question about this story? Ask your question
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- SubjectServices & solutions
- CompanyTechnolec