Innovative gas analysis, even in small process pipes

Gas analysis plays an important role in industrial processes, particularly in sectors where precise control of gas flows is essential for safety and efficiency. Gas analysers have traditionally been associated with large pipes and stacks, but the technology has advanced considerably in recent years and is now also suitable for smaller process pipes. One important example is the use of Tunable Diode Laser (TDL) analysers, which are used in many industrial environments for their accuracy and speed.

High resolution with Tunable Diode Laser (TDL) analysers in DN50

When we think of a Tunable Diode Laser analyser (TDL), we usually picture robust housings mounted on either side of a large stack, several metres in diameter. A laser source on one side and a detector on the other. That image holds true, until Mettler Toledo launched its “Probe Type” analysers just over ten years ago.

Small but perfectly formed

The process industry is not just about stacks and large pipes measuring one or two metres across. Typical process pipes have a diameter of 50 to around 300mm (DN50-DN100). This is not feasible with a conventional TDL analyser. The new design makes it possible. “Probe Type” analysers are designed with the laser and detector housed in a single unit, so only one flange connection is needed. The laser beam passes through the probe and is reflected back to the detector by a special reflector, the so-called corner cube. The laser beam therefore passes through the probe twice, making the optical path length (OPL) twice the physical length of the probe.

A practical example

In a metal industry process, the oxygen concentration in the gas stream must be measured. Because of the risk of explosion, the oxygen concentration must be kept as low as possible (< 1%), usually close to 0%. This is a safety measurement, so the analyser’s response time is critical and must be well below 5s. The pipe has a diameter of DN80. The temperature can reach 120°C at a pressure of 4bar (absolute).

None of this is particularly extreme, but it is still quite a challenge. A wafer cell analyser, a circular flow-through cell with a diameter of DN80, is the ideal solution. Under the specified process conditions, this configuration can measure the oxygen concentration with a resolution better than 0,2% and a response time of less than 2s.

Smaller pipe, but a longer OPL

For applications in smaller pipes such as DN50, where higher resolution (> 0,1%) is required, Mettler Toledo has developed a unique concept. The so-called MR2 or MR3 (MR stands for MultiReflector) increases the OPL by a factor of two or three. Recall that the laser beam is reflected, doubling the OPL. The MR2 makes the OPL four times the pipe diameter. With MR3, it is six times the diameter. 

This makes Mettler Toledo a “Technology Leader” in TDL analysers with the GPro500.

Read the full blog post for more information about installation in small pipes. >>

A business enquiry for ELSCOLAB? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectServices & solutions
  • CompanyELSCOLAB
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.