Unique 3D-linearised differential pressure transmitter cuts time-consuming calibration

Differential pressure measurement remains one of the most widely used measurement techniques in industry. This is reflected in the growing demand for DP transmitters.
This technology is certainly not outdated. With innovative solutions, leading suppliers in the process industry are responding to stricter requirements for accuracy, long-term stability and connectivity, and above all, the functional safety of differential pressure measurement technology. KROHNE, a market leader in flow and level meters, is introducing the Optibar DP 7060 C differential pressure transmitter, in which every measurement undergoes complete 3D linearisation, a market first.
As a leading supplier of measurement instrumentation, KROHNE offers complete DP, flow and level solutions, with sizing, engineering and documentation tailored to each specific application. The new Optibar DP 7060 C differential pressure transmitter not only provides accurate differential pressure readings everywhere, but also measures static pressure in the process line. Uniquely, every DP measurement undergoes complete 3D linearisation, characterising it across the full operating range: measurement range +/- DP, temperature between -40 and 85 °C, and static line pressure from 0 to 160 bar. This makes KROHNE the only manufacturer to perform 100% 3D linearisation and calibration on every DP transmitter.

The measuring cell makes the difference
A new measuring cell, which is 100% linearised and calibrated, makes the difference. The starting point is a purely mechanical design with advanced monocrystalline silicon piezoresistive sensors for differential and absolute pressure, the filling process, and the linearisation of external effects caused by static pressure and temperature. In the measuring cell, the individual pressures on the high-pressure and low-pressure sides are transmitted via a diaphragm and fill fluid to the primary sensors in the fluid capsule. To ensure a stable design and good accuracy at high process pressures and varying ambient temperatures, the effects of these influences must be eliminated in three stages: intelligent mechanical design, electronic compensation capabilities and linearisation. The effects of high line pressures and unexpected overpressure must also be minimised. The diaphragms are matched to the capsule’s base shape, limiting mechanical movement so that it remains within the elastic properties of the material. This prevents plastic deformation that could alter the measurement effect. The effect of ambient temperature is further reduced by making the capsules smaller and reducing the volume of fill fluid. The capsule is filled with precisely dosed volumes of degassed fill fluid in a controlled, automated environment, and then further processed as part of the 3D linearisation.
Complete 3D linearisation
To meet stricter requirements and time pressures during commissioning and maintenance, the capsule is equipped with three sensors for differential pressure, absolute pressure and temperature. The effects of residual static pressure and ambient temperature are linearised. To do this, mechanically prepared measuring capsules are mounted in batches on a fixture and placed in a heating chamber. The capsules undergo a linearisation cycle, producing a 3D matrix of linearisation coefficients, which are incorporated into a correction polynomial and uploaded to the front-end electronics. This enables the amplifier electronics to provide correct digital measurement values. A second calibration is performed in the heating chamber to ensure that performance meets all specifications. After calibration, the measuring capsules can be adapted to customer-specific requirements for HMI, communication, accessories and other functions.

Industrial processes
A number of important steps must be completed before a conventional DP transmitter can operate properly in an industrial process. After mechanical installation, the typical zero measurement is performed and the range is calibrated. In applications involving high static pressure, the transmitter is isolated from the process for calibration. The transmitter must also be reverified regularly. KROHNE’s 3D-linearised differential pressure transmitter significantly reduces the number of time-consuming calibrations. The transmitter also needs to be reverified less frequently, reducing TCO. The internal absolute pressure sensor and complete 3D linearisation prevent deviations caused by regular changes in line pressure, making periodic readjustment unnecessary. Standardised process connections, fast installation routines in twelve languages, various mounting options and a modular HMI speed up and simplify installation. Bluetooth communication makes commissioning and checking child’s play.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectSensors & vision



















