Process & instrumentation

Smart control valve diagnostics help prevent downtime

Text and images Valérie Couplez

De extreem veeleisende test in de warmwalserij van ArcelorMittal Belgium heeft de regelklep van FOCUS-ON met glans doorstaan.
De extreem veeleisende test in de warmwalserij van ArcelorMittal Belgium heeft de regelklep van FOCUS-ON met glans doorstaan.

Measurement and control instruments are rarely put to a tougher test than in steel production. At the hot strip mill at ArcelorMittal Belgium in Ghent, FOCUS-ON is proving that its smart control valves are more than up to the task. They ensure that just enough water is sprayed between the strip and the roll to produce steel coils. The control valves offer not only better control, but also extensive diagnostic capabilities, which have already prevented several production stoppages.

The thick steel slabs, up to 22 centimetres thick, coming from the steelworks are reduced to around 3 centimetres in the roughing mill during rolling, before being transformed in the finishing mill into strips between 1.25 millimetres and 13 millimetres thick. These can then be wound into coils for delivery to customers or further processing in the cold rolling mill. The hot strip mill at ArcelorMittal Belgium is divided into two automation zones: ‘furnaces-roughing mill’ and ‘finishing mill-coilers’. “During finish rolling, the pick-up is a particularly time-critical process for surface quality,” says Filip Vanhaelst, automation technicians coordinator for the finishing mill-coilers. “The skin cooling, in this case water, has to reach the space between the strip and the roll at the right moment. If it arrives too late, the roll burns. If it arrives too early, you won’t get a grip on the strip to roll it.” 

From left to right: Filip Vanhaelst (ArcelorMittal Belgium), Niels Van De Walle (ArcelorMittal Belgium), Wim Lintermans (KROHNE) and Georges Borst (FOCUS-ON).

Expertise combined in a smart control valve

Previously, this was done using a separate control valve and flow meter. “That solution offered too few diagnostic capabilities. We could extract some information from the flow meter, but had no feedback on the valve’s position or status. As a result, we detected faults too late, losing valuable production time and product,” adds industrial control technician Niels Van De Walle. At a trade fair, the ArcelorMittal team had come across a new product: FOCUS-ON’s smart control valves. FOCUS-ON is a joint venture between KROHNE and SAMSON. The two companies combined their extensive knowledge and experience to develop a control valve with an integrated flow meter. “Together, they can use a single product to build and maintain a control loop,” explains George Borst, FOCUS-ON’s business development and marketing manager. “Maintenance is based on integrated diagnostic models for phenomena such as cavitation, flashing and wear, as well as simple data such as flow and pressure trends. This allows the valve to quickly provide insight into process changes or valve diagnostics.” 

Extreme demands, good results

The potential was immediately clear. A test rig was set up alongside the existing valve in the hot strip mill to check whether it would perform as required under these difficult conditions. The trial was a success. Van De Walle: “Pressure is now measured at the valve inlet and outlet, so we know exactly what the water is doing and whether any shut-off valves are closed unnecessarily, preventing us from cooling. If a component is not working properly, an alarm is triggered.” However, the solution was not entirely plug-and-play. “We actually demand much more extreme performance from the valve than is standard. At first, we couldn’t achieve the response times we were used to, which were 0.7 seconds. After a number of software updates, combined with a larger diameter compressed-air supply, we are now achieving faster times. In future, we want to see what more we can get out of it,” says Vanhaelst.  

Previously, ArcelorMittal Belgium regularly experienced faults with valves and controllers. Now, FOCUS-ON’s smart control valve detects problems immediately.

Diagnostics provide insight into the process

Even without the higher response speed, ArcelorMittal was already very pleased with its new smart control valve, thanks in particular to its diagnostic capabilities. “We’ve made real progress in that area. In the last six months under the old system, we regularly encountered faults with the old valves or controller. Now we spot problems immediately. For example, during a start-up, there was an issue with the compressed-air supply. The new valve immediately showed us where to look for the cause. That saves a huge amount of time, which is in short supply when restarting the hot strip mill after a maintenance shutdown. A quick diagnosis is crucial,” says Van De Walle. The built-in redundancy also impressed both men. Vanhaelst: “In effect, it works with a digital twin. It knows how the process should operate and can carry out a flow measurement based on a differential pressure measurement if the flow sensor fails.” 

Further roll-out

The trial in the hot strip mill therefore gave the FOCUS-ON control valve flying colours. “If we need a new control valve in future or have to retrofit an existing one, we will certainly consider this one, especially if it also becomes available in larger diameters,” concludes Vanhaelst, with a wink at Borst. 

Een zakelijke vraag aan KROHNE Belgium NV? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectProcess & instrumentation
  • CompanyKROHNE Belgium NV
  • CompanyFOCUS-ON VOF
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.