Reliable, safe and fast gas measurement for a range of applications
Text Evi HussonImage Elscolab

Many companies in the chemical and pharmaceutical sectors want to use an analyser system to measure gases such as oxygen in a range of applications, with a fast response time, high reliability and ease of use, and minimal maintenance. Mettler Toledo has therefore launched the GPro500 TDL (Tunable Diode Laser). Dirk Vleminckx and Harry Geeraedts of Elscolab explain how the gas analyser works.
In many production processes, it is important to measure the gases present, such as oxygen, carbon monoxide, CO2, moisture and toxic gases. For example, the presence of unwanted oxygen can create an explosion risk. Companies want to detect unwanted gases early so they can adjust their processes in good time. “This is possible with Tunable Diode Laser (TDL) analysers,” explains Dirk Vleminckx, Application Specialist at Elscolab.
“Conventional TDL analysers have a separate light source and detector. This causes many alignment problems, resulting in a lot of lost time and the need for frequent maintenance. Both units also need separate power and purge gas supplies.”

Transmitter and receiver in one
Mettler Toledo has therefore brought an innovative solution to market: the GPro 500. “This new generation of analyser integrates the transmitter and receiver into a single system, eliminating the need for alignment. If there is vibration or distortion, the laser source and detector move in the same direction. This setup offers a fast response time and high accuracy, and eliminates the need for alignment, resulting in minimal maintenance.”
A range of variants
“There are several variants of the GPro 500,” adds Harry Geeraedts, Sales Engineer at Elscolab. “Dust is a challenge in gas analysis. If your processes generate a lot of dust, powder or smoke particles, these can block the light. To prevent this, an in-situ metal filter can be installed in the gas analyser, with a pore size matched to the size of the particles in the dust present.”
Moisture can also cause problems. Geeraedts explains: “Moisture in the form of droplets can also reach the lens or detector. You want to prevent this. In these situations, you can choose a PTFE filter instead of a metal filter. It is designed to stop water droplets, preventing them from causing problems in the optical path length (OPL).”

Wafer cell for smaller pipes
Vleminckx also highlights an interesting and innovative option. “TDL analysers are usually installed in large, robust pipes with an optical path length of up to ten metres. However, many processes use smaller pipes, such as DN50, DN80, DN100 or DN200, where conventional analysers are difficult to install. Mettler Toledo has therefore developed the wafer cell, a circular flow-through cell that can double or triple the optical path length if required. This makes it easy to measure gas concentrations with a fast response time, even in smaller pipes.”
Automatic alerts
“There is a solution to every challenge,” says Geeraedts. “The analysers offer many benefits. Their fast response time means you can act quickly when necessary. The systems are also designed to be maintenance-free. The TDL can check itself and issue an alert, for example, if it becomes contaminated. With a Safety Integrity Level 2 (SIL2), it is an extremely reliable and safe system that has become indispensable in industry.”

A business enquiry for ELSCOLAB? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeLess downtime through maintenance
- SubjectProcess & instrumentation
- CompanyELSCOLAB