Reliable pressure measurement in emulsion line prevents pump failures

Nog vóór de officiële marktintroductie in augustus 2019 werd de nieuwe VEGABAR 38 geïnstalleerd bij FrieslandCampina Kievit om een hogedrukpomp te bewaken.
Nog vóór de officiële marktintroductie in augustus 2019 werd de nieuwe VEGABAR 38 geïnstalleerd bij FrieslandCampina Kievit om een hogedrukpomp te bewaken.

Some measurement points just never seem to work properly. For years, users try to get stable readings from them, but the result is always the same: failures or unreliable measurements.

That was exactly the situation in an emulsion line downstream of a pump at Kievit, part of FrieslandCampina. Only after the VEGABAR 38 was installed have reliable readings become available, and pump failures are now a thing of the past.

When your taste buds explode, it is not just down to the flavour, but often to a product’s consistency as well. The Dutch company Kievit specialises in creating just these kinds of taste sensations. “We work with our customers to develop ingredients for the food and beverage industry, including foaming creams, coffee and cocoa mixes, fat powders, whipping agents, functional blends, micro-encapsulations and cake emulsifiers,” says Ger van den Berg, responsible for work preparation and planning at Kievit’s Meppel site. FrieslandCampina Kievit has relied on VEGA sensors for pressure and level measurement for some fifteen years. “I attach great importance to the reliability of the instruments and know that we can rely on them without having to worry,” explains Van den Berg. VEGA recently proved this again at a measurement point that had been a problem for years.

De VEGABAR 38 beschikt over een gekleurde 360° weergave van de schakelstatus. Daarmee is in een oogopslag te zien of de meetapplicatie werkt, of de sensor schakelt en of er misschien een storing in het proces aanwezig is.

The VEGABAR 38 features a coloured 360° display of the switching status. At a glance, it shows whether the measurement application is working, whether the sensor is switching and whether there may be a fault in the process.

Pressure sensor monitors emulsion

This section of the system monitors the emulsion. As soon as the emulsion reaches a certain temperature, it is pumped onwards by a high-pressure pump. A constant pressure must be maintained in this circuit to supply the high-pressure pump. A pressure measurement point was therefore installed downstream of the pump to detect at an early stage when the filter starts to become clogged. “Pressure instruments from another manufacturer were used here in the past. Their limited service life meant they kept causing problems,” explains Van den Berg. Other measurement principles, such as flow measurement, did not work well either. On the one hand, moisture ingress caused problems; on the other, the diaphragm often failed. “However, this measurement is essential to the overall process, as it is the only way to monitor filter contamination, which is crucial to keeping the pump running smoothly,” says Van den Berg.

Failures reduced to a minimum

The new VEGABAR 38 was therefore installed before its official market launch in August 2019. Its patented CERTEC® measuring cell ensures that the instrument can withstand all the conditions it may encounter in operation. The ceramic diaphragm in the measuring cell is extremely robust and resistant to overload, making it exceptionally well suited to high pressures and pressure surges. Since its installation, the VEGABAR 38 has reduced failures caused by filter contamination to a minimum by reporting pressure increases in good time. The VEGABAR 38 features a coloured 360° display of the switching status. At a glance, it shows whether the measurement application is working, whether the sensor is switching and whether there may be a fault in the process. The filter can then be cleaned to restore sufficient flow and prevent the pump from breaking down.

Sinds de installatie heeft de VEGABAR 38 uitval door filterverontreiniging tot een minimum teruggedrongen door tijdig een toename van de druk te melden.

Since its installation, the VEGABAR 38 has reduced failures caused by filter contamination to a minimum by reporting pressure increases in good time.

Easy installation and commissioning

As this was essentially a pilot project, the VEGA team was on site during installation. “But in future, we will do it ourselves. Installing and commissioning VEGA instruments is very straightforward thanks to the PACTware software or the VEGATOOLS app, which enables wireless (Bluetooth) configuration via smartphone or tablet,” says Van den Berg, who has long valued the quality and reliability of VEGA instruments and VEGA’s service. “I like the colour. The eye wants something too, after all,” laughs Van den Berg, adding that the pressure sensors have worked without problems since being put into operation. And should a problem arise, Van den Berg knows he can count on VEGA. “Whenever I had a question, VEGA always helped me straight away.” He recalls a particular raw material consisting of a very light powder with a low r (DK) value, which made it difficult to detect. “Together with VEGA’s account manager and engineers, we worked on it for a long time until we finally achieved a good result. Getting that measurement right back then gave us a solid foundation of trust,” concludes Van den Berg.   

Question about this story? Ask your question

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectProcess & instrumentation
  • CompanyVEGA N.V.
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.