Modular solution for dosing speciality chemicals

The right measurement technology leads to more efficient and safer processes. EGM, a manufacturer of process and chemical dosing and make-up systems, chose a modular solution from Krohne for dosing speciality chemicals. This article explains the choice.
US-based EGM produces process and chemical dosing and make-up systems for various industries. For the paper industry, the company designs and builds ASA emulsification systems, among other equipment. ASA, short for alkenyl succinic anhydrides, is a medium that is crucial to paper production, making the paper water-resistant.

Process
The ASA emulsion is made by combining ASA with a cationic emulsifier and dilution water. The mixing ratios depend on the properties of the paper fibre, the paper machine’s production speed and the ‘type’ of paper being made. The mixture’s cationic charge ensures that it remains attached to the fibre as the sheet of paper is formed. It then passes through the dryer, where the chemical ‘cures’, making the paper water-resistant.
Flowmeter requirements
To monitor this process, fast, accurate and repeatable flowmeters are required. They must work very effectively and accurately with a control system to produce the required emulsion. EGM tested Krohne meters and found them suitable for this application. They fully met the requirements for accurate and repeatable flow measurement. They also proved cost-competitive.
The dosing systems were equipped with the OPTIMASS 6400 C Coriolis mass flowmeter and the OPTIFLUX 4300 C electromagnetic flowmeter. Since ASA is an oil-based, non-conductive chemical, the OPTIMASS 6400 C is used to measure the ASA flow. The Coriolis mass flowmeter delivers the required performance in dosing applications. It is designed for highly accurate measurements, with an error of just 0.05% in liquid applications and excellent repeatability. Thanks to Entrained Gas Management (EGM), the flowmeter continues measuring across a wide range of gas fractions and under complex flow conditions.

Critical applications
The water-based emulsifier is measured using the OPTIFLUX 4300 C. EGM also uses the electromagnetic flowmeter to measure primary and secondary dilution water, as well as the recirculation rate of the mixing pump. The flowmeter is suitable for critical applications requiring high accuracy and extensive diagnostic functions. A wide range of liners and electrode materials makes it suitable for many products, including numerous corrosive or abrasive chemicals.

PLC
Compact versions of the flowmeters are used on skids. The measurements are sent to the user’s PLC. Using the OPTIMASS 6400 and OPTIFLUX 4200 flowmeters ensures that the sizing emulsion is always correctly composed and that all flows are accurately controlled. The PLC is programmed to adjust the additives in real time when the paper machine’s production speed changes.
As well as delivering accurate dosing and repeatable performance, the flowmeters can be installed in a compact layout in a relatively small space, making the system easier for the end user to maintain.
For more information:
www.be.krohne.com/en/products/flow-measurement/flowmeters
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- ThemeFrom design to flexible machine