How can you achieve the lowest TCO for pumps?
Text Valérie CouplezImage iStock

Good planning can reduce the Total Cost of Ownership (TCO) over the lifetime of a pumping system. There are many ways to achieve this. Correctly matching the pump to the application is crucial. Analysing pump performance in existing applications, where possible, should be part of the selection process. Oversizing pumps “to be on the safe side” is a common mistake and one of the biggest causes of excessive energy consumption.
There is no one-size-fits-all solution for improving a pump’s operational efficiency, as many factors affect performance once it has been installed and commissioned. What pump manufacturers can do is develop a pumping system that makes optimum use of energy-saving components and technologies, and support customers during the selection and specification process.
Don’t waste energy
The efficiency of the hydraulic components must be matched precisely to the required performance. Impeller diameter is one specific hydraulic parameter that affects performance. Oversized impellers waste energy. Trimming the impeller’s outer diameter to achieve the exact required flow rate can deliver energy savings of up to 10%. This can also reduce maintenance costs and extend service life.
Control your pump speed
Controlling pump speed offers by far the greatest savings potential, yet matching power consumption to actual demand is still far from standard practice. Technology is available to match pump speed precisely to the required output. Using a variable frequency drive provides dynamic pressure compensation and delivers additional savings at low flow rates. Using a throttling valve is another approach. Variable frequency drives can, however, cut energy consumption by up to 60%. For pumps that run continuously, the higher initial cost of a variable frequency drive is quickly recouped through lower energy costs.

Know your BEP
All pumps have what is known as a ‘best efficiency point’ (BEP): the combination of head and flow rate at which the pump operates most efficiently. Operating pumps at or near their BEP prevents problems such as cavitation and vibration, which can cause impeller erosion or accelerated wear of bearings and seals. Selecting a pump with a BEP close to the system’s required operating point helps reduce operating and maintenance costs in the long term.
What gets measured gets managed
Advanced measurement and data-logging equipment can help establish the pump’s actual load profile and compare it with the design specifications. Instruments measure suction pressure, discharge pressure, differential pressure and head. Calculating these values produces a pump curve showing the operating range and provides a load profile for the pump. This enables the manufacturer/supplier and user to see whether the pump is operating cost-effectively or whether availability is at risk. The results:
- Potential savings can be identified (energy efficiency analysis).
- The causes of any damage can be established (damage analysis).
In-situ measurements using instruments connected to a data logger create an operating record of process and vibration variables. Portable performance measurements in the control cabinet can determine the pump’s effective power, regardless of location.
Unlock the greatest potential
Pumps are system components that consume large amounts of electricity, typically around 32% of TCO. This represents significant savings potential. In terms of the drive, the motor in pump units can deliver savings of around 10%. Optimising the pumps’ hydraulic efficiency can yield savings of up to 20%. Analysing and optimising the entire circuit can increase the potential to as much as 60%
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectProcess & instrumentation