Dream team tackles heat and condensation

In beide secties van de vacuümreactor heersen totaal verschillende condities.
In beide secties van de vacuümreactor heersen totaal verschillende condities.

This is why conventional differential pressure transmitters have limitations when it comes to monitoring levels in the production of additives for paints and plastics. VEGA’s electronic differential pressure measurement technology is different. Thanks to its innovative combination of ceramic and metallic measuring cells, it delivers optimum safety and highly accurate measurements.

BASF is one of the world’s leading producers of additives for plastics. These substances help make plastics colourfast, abrasion-resistant, heat-resistant, elastic, crystal-clear and more. Under precisely defined conditions, raw materials are converted into additives through a series of chemical reactions. This takes place in a fully automated process in which every measured value is carefully checked and stored to ensure the correct dosage. Reliability is crucial at the Kaisten site, as the end product is an essential building block for BASF. Any downtime has far-reaching consequences. “Even the smallest problem interrupts a complex process. In practice, that means working weekends and overtime for us,” explains Marcus Stoll. He is Head of Specialist Workshops EMSR at BASF. Together with his team, he is responsible for ensuring the highest possible availability.

Protecting processes from silicone oil. This is one of the building blocks in BASF’s efforts to achieve the highest possible safety at every process stage at its site in Kaisten, Switzerland.

In the eye of the storm

Vapour pressure plays an important role in the production of these additives. The more precise the measurement, the clearer the picture of the processes and the more efficiently they can be managed. It also provides additional information on how process components can be optimised. The conditions, however, are harsh: aggressive substances and acids that can leave deposits on tank walls, as well as high levels of vacuum and steam. This is where VEGA pressure sensors and their reliable measurements make all the difference. In the past, BASF engineers used conventional differential pressure transmitters for this application. However, they decided to switch to electronic pressure sensors that work without silicone oil-filled capillaries or remote seals. “Choosing a system based on CERTEC ceramic measuring cells was an obvious decision, particularly because of their reliability when handling abrasive substances. After all, our plant has to run 24/7,” Stoll emphasises.

Marcus Stoll: “The combination works like a dream team. As far as I know, VEGA is the only company to offer this combination. This gave BASF a solution to two challenges.”

One solution for two extremes

The highly robust CERTEC ceramic measuring cell was ideal for the lower section of the BASF vacuum reactor, which contains hot, aggressive solvents. Conditions in the upper section, by contrast, were completely different. Here, extreme steam levels cause condensation in the measuring cells, which can lead to inaccuracies. The obvious solution was to use differential pressure transmitters, in this case based on METEC metallic measuring cells. Condensation and humidity do not adversely affect these measurements. “The values measured in the upper section are now, and remain, acceptable and highly accurate under all conditions,” says Stoll. However, the high temperature of the solvent below could cause the measured values to drift. Solving this required expertise, a willingness to experiment and, above all, close collaboration between BASF and VEGA. 

A combination that makes a dream team

The unexpected solution was to use an innovative electronic differential pressure measurement system that combines a ceramic and a metallic measuring cell. The two sensors measure their respective values independently and then calculate the differential pressure in the primary sensor. This is made possible by using identical electronics behind these two very different measuring cells. Stoll says: “The combination works like a dream team. And as far as I know, VEGA is the only company to offer this combination. This gave BASF a solution to two challenges.” 

Question about this story? Ask your question

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectProcess & instrumentation
  • CompanyVEGA N.V.
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.