Accurate level measurement, even in the toughest conditions

As a supplier to the pharmaceutical industry, you need to work quickly, flexibly and with extreme precision. These are exactly the same qualities you expect from your level measurement instruments. That is why Aji Bio-Pharma in India has relied on the VEGAPULS 64 radar for five years.
Ajinomoto Bio-Pharma Services, with sites in Belgium, the US, Japan and India, offers a broad range of services in development, cGMP manufacturing and aseptic filling for small and large molecules, APIs and intermediates. It uses a variety of innovative platforms and capabilities for preclinical studies and pilot programmes through to commercial-scale production. It recently announced an agreement with Humanigen to manufacture Lenzilumab. This drug, currently in Phase 3 development, is one of the few treatment options for patients hospitalised with Covid-19.
The Indian site in Visakhapatnam has been in operation since 2011. It was designed and built to meet the GMP operating standards and quality systems of Aji Bio-Pharma’s Belgian sites, and approved by the FDA. For more than five years, the company has relied on VEGA measurement technology for level measurement in an API intermediate plant. The VEGAPULS 64 radar level sensors operate at temperatures between -25 and 150 °C, meet ATEX requirements and are used with various process connections (DN50 / DN80 / DN100 flange).

Optimum quality and yield
Most of the media to be measured in the plant are liquid and suspended. Accurate measurement is essential to meet stringent quality requirements and achieve higher yields. A level that is too high would cause an overflow, while one that is too low would lead to pump cavitation. The level is also an important parameter for an efficient distillation process. Determining the interface directly affects product quality and yield.
The operating conditions include just about everything that can make life difficult for measuring instruments. Agitators cause foaming and turbulent surfaces, while contamination, high temperatures and vibration are also present. Acidic vapours come into direct contact with the sensor. Explosion protection (Zone 1) and SIL requirements must also be observed. As a result, the process in the reactor vessel had previously been monitored manually by the operator.
Reliability makes the difference
Radar measurement technology was chosen for its high accuracy compared with ultrasonic or differential pressure measurement. “I don’t know of another sensor that can match the VEGAPULS 64 for accuracy,” says Vikramsena Reddy, project manager at Ajinomoto Bio-Pharma Services.
This is mainly due to its narrow 3° beam angle. Thanks to its focused radar beam, the sensor delivers reliable measurements within a very narrow radius. Agitators in the tanks can also cause interference, but the sensor’s radar signal simply passes these obstacles by. Product build-up on the agitator or tank walls is no problem either. “This enabled us to increase process yield,” adds Reddy.
The wider dynamic range of the VEGAPULS 64 also provides a more reliable signal, as well as greater accuracy. VEGA also offers materials tailored to the stringent requirements of the pharmaceutical sector, in accordance with FDA, EC 1935/2994 and GB Standards. The hygienic design meets all standards in accordance with EHEDG and 3-A Sanitary.

Practical in day-to-day operation
“Installation is really straightforward, the sensor is suitable for any flange size, and its narrow beam angle in particular means it can be installed anywhere on the tank. We configured and calibrated the sensor via Bluetooth, without any help from VEGA,” recalls Reddy, who appreciates that every VEGA instrument can be configured in the same way. “For identical tanks, the parameters can be transferred from one instrument to another almost by copying and pasting.”
For Reddy, the switch to VEGA radar level measurement has clearly paid off. As well as reliable level measurement, it is now possible to determine the interface accurately. Although the sensors were installed in existing tanks, the costs of the flange and mechanical modifications were kept under control. “After installation, we could more or less forget about the measuring point. There is no longer any need for regular calibration either,” says Reddy, despite the fact that some of the media have a high acid content. VEGA radar level measurement has now become the company’s standard.