News

Precision measurement, even in extreme conditions

Precision measurement, even in extreme conditions

Standing still means falling behind. As a world leader in measurement solutions for industrial process applications, Krohne launches a whole host of new products every year. In 2018, too, the R&D team was working at full capacity, resulting in numerous innovations. Here is a selection of the many products added to the range this year.

The Krohne Optiflex series has been expanded with four new modular TDR level transmitters. The 7200 is designed for level and interface measurement of liquids in storage and process applications in the chemical, oil and gas industries. It offers an accuracy of ± 2 mm and is fitted with SIL 2/3-certified current and relay outputs. The 8200 C/F/S is a level transmitter for measuring liquids at high temperatures and pressures. Thanks to its single or double ceramic process seal system and patented Dynamic Gas-phase Compensation, this device is suitable for use in extreme conditions. The 3200 C/F gives the food, beverage and pharmaceutical industries a level transmitter for liquids that fully meets their sectors’ hygiene standards. This is thanks to a design intended for processes with a CIP/SIP cleaning cycle, a stainless steel housing and a meter that is unaffected by steam, foam and condensation. Finally, the 6200 C/F is a level transmitter for solids, from granules to powders, with a tensile load capacity of up to 3,500 kg. It offers a high level of protection against electrostatic discharge and is unaffected by dusty environments and sensor build-up.

Now with Profinet I/O option
The universal MFC 400 Coriolis mass flowmeter signal converter is also now available with a Profinet I/O option. “This means that all Krohne Optimass x400 Coriolis mass flowmeters, in both compact and field versions, can be equipped with industrial Ethernet communications, in addition to the existing Hart 7, Foundation Fieldbus, Profibus PA and DP, and Modbus options,” says sales engineer Wim Lintermans. “With Profinet I/O, all the meters’ measurement, process and diagnostic information is directly available via a single communications channel. This allows the new meters to be integrated easily: the MFC 400 supports network functions such as Auto-Negotiation, Auto Crossover, Auto Polarity and network diagnostics. Once connected to the network, it is automatically added to the communications path topology. With Media Redundancy Protocol support, the MFC immediately switches to an alternative communications path if an instrument or communications line fails. There is no longer any need for a web server: standard functions such as zero-point calibration and counter reset can be carried out directly.”

Meetoplossingen

The Optiflex 3200 C/F gives the food,
beverage and pharmaceutical industries a level
transmitter for liquids that fully meets their sectors’ hygiene standards.

Meetoplossingen

The Optiflex 8200 C/F/S is a level transmitter for measuring liquids at high temperatures and pressures.

Meetoplossingen

The Optiflex 6200 C/F is a level transmitter for solids, from granules to powders, with a tensile load capacity of up to 3,500 kg.

Meetoplossingen

The Optiflex 7200 is designed for level and interface measurement of liquids in storage and process applications in the chemical, oil and gas industries.

Unique measurement of solids
Finally, we would like to highlight the new generation of analytical sensors for measuring solids. The Optisens TSS 3000 and 7000 are glass-free optical sensors with multiple path lengths for different concentration ranges. They use unique four-beam technology with alternating light sources, offering greater reliability than conventional two-beam technology. “Two NIR LED (880 nm) light sources and two detectors compensate for measurement errors caused by dirt, build-up or changes in the light source,” says Lintermans. “They also measure directly through the PP layer, making measurement errors and sealing problems caused by glass windows a thing of the past.” The Optisens TSS 3000 is suitable for wastewater applications and, with its 1¼ NPT thread, can be used in retractable or immersion assemblies. The Optisens TSS 7000 is designed for hygienic applications with Tri-Clamp or Varivent process connections. 

“Finally, we have launched a menu-driven analytical transmitter for Optisens TSS, pH/ORP and COND sensors,” says Lintermans. “The Mac 300 can transmit signals from up to three connected analytical sensors to the control system via up to six analogue 0/4…20 mA outputs, relay outputs or optical Modbus. The transmitter has an LCD display in a robust housing (IP66/67, NEMA 4/4X) for wall or panel mounting. Live trending and data logging are available as options, and an SD card slot is provided for saving parameter settings or uploading new firmware.”  

Meetoplossingen

Question about this story? Ask your question