Accurate biogas monitoring

The wastewater treatment plant in Tiel is equipped with a sludge digestion system. It uses sewage sludge to generate biogas, which is used to meet energy requirements. As a result, the Tiel wastewater treatment plant is fully energy neutral. The biogas flow is accurately monitored by an ultrasonic flowmeter with integrated temperature measurement.
Waterschap Rivierenland has set itself the goal of operating entirely on renewable energy by 2030. The wastewater treatment plant in Tiel plays an important role in this. It is equipped with a digestion tank in which sewage sludge is digested at a constant temperature of 52 °C. This digestion process produces biogas, which is used to meet the treatment plant’s total energy requirements.
Wet biogas calls for a specialised gas flowmeter
To ensure the energy plant can be controlled and protected, the biogas flow between the digestion tank and the energy plant must be accurately monitored. The biogas leaving the digester is wet, unpressurised and has varying methane and CO2 concentrations. Measuring this gas flow therefore requires a specialised meter. Waterschap Rivierenland is also required to monitor and record all excess gas for the supervisory authorities. KROHNE developed the OPTISONIC 7300 ultrasonic gas flowmeter with integrated temperature measurement specifically for biogas applications of this kind. It enables the corrected gas volume flow to be measured accurately in real time. The meter is unaffected by wet gas and can therefore be installed directly downstream of the digester. Regardless of the gas composition, ultrasonic measurement also makes it possible to measure the multivariable gas composition without pressure loss.
The OPTISONIC 7300 cuts costs
Because the OPTISONIC 7300 can determine the methane content of the gas flow from the measured speed of sound, a separate analyser is no longer required. This immediately saves on installation costs. Installing an ultrasonic gas flowmeter is also a smart move when it comes to maintenance costs. With its integrated gas analysis and installation-independent, integrated mass flow measurement, the OPTISONIC 7300 significantly reduces maintenance costs.
Question about this story? Ask your question
Keep following this
Get an email when a new story is published. No account needed.
- SubjectNews