Moving and securing samples safely: made possible by ACE industrial gas springs and clamping elements

To process samples for biomedical research as quickly as possible, laboratory staff need ergonomic workstations. For a new sampling-head holder design, the engineers chose high-quality machine components that can safely control rapid movement and reliably secure loads weighing up to 10 kilograms.

Taking unconventional approaches to design solutions is nothing new for tech-solute GmbH. The company, based in Bruchsal, Germany, near Karlsruhe, specialises in technical product innovations. Initially, its focus was purely on concept development, but its service offering later expanded in response to growing customer demand for technical ideas to be developed into near-series designs. Today, tech-solute develops a wide range of ideas for series production, builds prototypes and works on both its own innovation processes and those of its customers. For example, tech-solute recently developed an assembly aid for handling laboratory samples for a customer in biomedical measurement technology, and then built a prototype. This new design allows the sampling head to move freely at different heights and be positioned correctly without effort. The assembly aid can then be securely fixed in the best possible position. Four clamping elements and an ACE Stoßdämpfer GmbH gas spring are integrated into a single design.
Fast, cost-effective and efficient
By intelligently combining these and other components, and using agile product development, the mechanical engineering team led by project manager Philipp Aders at tech-solute quickly built a functional prototype of a sampling-head holder. The prototype has already proved itself in production tests. Dr.-Ing. Dirk Schweinberger, one of tech-solute’s two founders and its managing director, explains the approach: “We were looking for a fast, cost-effective and efficient solution, so we planned to use standard components. We already knew the benefits of ACE machine components from previous projects. The clamping elements allow samples to be secured in any position, while the gas spring ensures smooth upward and downward movement without requiring much force.” Ease of use is central to the sampling head design. With tech-solute’s new design, all four axes can be adjusted independently. The relevant axis can be unlocked with one hand while the sample is repositioned with the other. This is much easier than with the system used previously. “Until now, the direction of movement was not always entirely predictable with samples weighing up to ten kilograms. Staff therefore had to secure, hold and position the samples manually as an additional precaution,” says Philipp Aders, describing the time-consuming process. This could lead to errors. The new assembly aid has now eliminated that problem. “The four axes make it possible to position samples so that all the areas technicians need to access are easily reachable.”


The solution: high-quality series components
The assembly aid is mounted on a height-adjustable table with a vertical aluminium linear guide. This allows the entire end of the rod to be moved up and down electrically. An ACE GS-22-250 gas spring is fitted to make it easier to raise and lower the sampling-head holder. ACE Stoßdämpfer GmbH’s online calculation tools were used to select the right component: https://www.ace-ace.nl/nl/berekeningen/snelheidsregeling/gasveren-online-berekening.html.
This makes it possible to provide a customised solution at short notice. In most cases, ACE industrial gas springs are ready for dispatch within 24 hours. Gas springs and gas traction springs are used in particular when reliable assistance for muscle power is needed from a hydraulic machine component. Once the sampling-head holder is in the desired position, an ACE linear guide clamping element secures it. The LOCKED PLK30-1-4B machine component is compact and guarantees maximum holding forces, even on lubricated rails. “It is released by a button on the swivel head, which uses compressed air to release the clamping unit,” says Philipp Aders. Additional clamping forces act on the housing mounted on the linear carriage. The assembly aid’s first rotary axis is located here, perpendicular to the linear guide. Two ACE R70-4B rotary clamps provide rotation and fixation. A PN63-20-2-4B rod clamp is also fitted midway between the rotary clamps. In addition, plain bearings ensure that when the rod clamp is released, rotation alone is possible, with no back-and-forth movement, and that the axis is secured in the intended position. These three axes are used to position the sampling head flexibly. All the components used for fixation are released by pneumatic valves. They are clamped in their normal state. Managing director Dr.-Ing. Dirk Schweinberger sums up: “At our customer’s request, we created a complete design that ensures an optimal interaction between controlled movement and secure fixation in any position required by laboratory staff.”