Minimum effort, maximum safety

A large footprint in the control cabinet, overcrowded cable trays and a complex distribution board installation. Anyone looking to safely switch off motors in conveyor systems using conventional methods faces a range of cabling and power distribution challenges. To make installation much easier, Wieland Electric has developed the podis MS 5HP motor starter. Not only is it the smallest motor starter for motors rated from 0.25 to 4 kW, it is also the first motor starter with integrated Safe Torque Off (STO) safety. This makes it the simplest decentralised solution for controlling asynchronous motors.
The podis MS 5HP motor starter is an extremely compact (178 x 261 mm), robust and user-friendly drive component for motors in the 0.25 to 4 kW power range. With this component, Wieland Electric is once again reinforcing its commitment to developing decentralised drive technology.
Thanks to the integrated STO (Safe Torque Off) function, the connected motor is torque-free, and the power supply can be disconnected entirely independently of the emergency stop circuit. As a result, STO circuits no longer need to be routed over long distances via a central distribution board and assigned to a specific power line, while still achieving the highest possible level of safety for people and machinery. This makes the system far less susceptible to interference, while also delivering significant benefits in terms of planning, inventory management and installation work.
In other words, it is a drive solution that is ideal wherever there are conveyor belts and space is limited. The advanced thermal design, combined with low-wear electronic switching, also helps ensure a long service life for the podis MS 5HP motor starter.

Decentralised power distribution
The innovative combination of starter functions enables decentralised power distribution and assignment of STO circuits in the field. What is more, the highest level of safety (SIL 3 PL e) can be achieved with minimal effort. All motor starters in the emergency stop circuit are connected to female STO connectors. The STO circuit is then monitored and controlled via an auxiliary power supply generated on site and a two-channel safety relay. Multiple STO circuits can be controlled from a single power source.
Using a power bus system such as Wieland Electric’s podis 5G6 brings further benefits by separating power from other signals. The power distribution for multiple motor starters and their motors can be combined in a single loop. This saves space in the cable trays and makes wiring the distribution board much simpler.
Wide range of applications worldwide
The podis MS 5HP motor starter has been designed to handle a power range of 0.25 to 4 kW. This makes it suitable for a wide range of applications, reducing the amount of stock users need to keep and helping them save on administrative costs. Purchasing and managing materials can be done with ease.
Ease of use was also a priority during installation and commissioning. The motor can be configured entirely using DIP switches. An intelligent web configurator guides users step by step through all the settings for the motor and the application in question. All they need to do is scan the QR code on the front of the motor starter with a smartphone or tablet. Decentralised control and diagnostics can be carried out from anywhere, at any time.
With international approvals such as CE and cULus, the podis MS 5HP is also suitable for use worldwide. It can also withstand demanding industrial conditions.
Een zakelijke vraag aan Atem NV? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- SubjectMotion, gears & drives
- CompanyAtem NV




















