Control & network

Sustainable automation with AS-Interface: fewer plugs, more connectivity

Text Bihl+WiedemanImage Bihl+Wiedeman

Sustainable automation with AS-Interface: fewer plugs, more connectivity

ASi is no longer just a flexible, cost-effective wiring solution. It is a technology that enables powerful automation solutions and also simplifies the implementation of functional safety. At their core, all generations of AS-Interface are based on the principle of simplicity: safety and standard devices in the ASi network are connected to an ASi profile cable using piercing technology, without special tools and exactly where they are needed. IO-Link devices, and in future IO-Link Safety devices too, can be connected easily using ASi-5 and integrated into Industry 4.0 and the associated IIoT structures. Bihl+Wiedemann's software suites provide intuitive, error-free and highly functional solutions for specific tasks and network topologies. The technology also stands out from a security perspective, as network participants are isolated from the outside world, preventing security vulnerabilities. In addition, all modern ASi devices from Bihl+Wiedemann support firmware updates in the field.

AS-Interface wiring with profile cable and piercing technology compared with wiring fieldbus modules using connectors and cables of different lengths.

Less is more. While other fieldbus solutions generally require coded connectors for both the bus connection and the power supply, which may follow different standards, ASi connectors are usually not needed to connect ASi modules, as these simply clip onto the profile cable. Pre-assembled connection cables are also unnecessary. These are needed, for example, to connect and power Ethernet modules, whereas ASi components can be flexibly connected to ASi or AUX profile cable cut to the required length, wherever they are actually needed. Connectors and cables alone account for considerable savings with AS-Interface wiring, of around 100 to 150 euros per module connection compared with Ethernet-based fieldbus solutions.

ASi profile cable compared with conventional parallel wiring.

Positive environmental impact

ASi also offers savings compared with parallel wiring, where each signal must be routed separately to the controller. The use of raw materials such as copper and plastics for ASi profile cable, as well as the energy required for its production, is considerably lower than for the individual cables otherwise needed. It also has a positive environmental impact at end of life, as it generates less waste. As a resource-efficient technology, AS-Interface is therefore more future-proof than ever. 

Working time is valuable too, particularly given the shortage of skilled workers, and the less of it that is wasted, the more is available. Thanks to its polarity-proof profile cable and piercing technology, AS-Interface is probably the most efficient wiring system on the market, saving not only materials but also time and therefore money. 

Unlike other fieldbus solutions, sensors and modules can be connected via ASi in a matter of seconds, without preliminary planning and commissioning time, or waiting for pre-assembled connection cables that have to be stocked in a wide range of lengths. There is no need to search for a suitable mounting point, risk using cables of the wrong length or incompatible connector coding, or work with up to four cables per module. What is more, an exceptionally large number of modules can be connected via just two wires to the gateway, all under a single IP address. This saves costly installation time, including when additional ASi participants are quickly integrated at a later stage, and noticeably reduces planning effort in mechanical and electrical design, as well as in service and maintenance. 

Comparison: IP address and IP67 connector requirements for integrating I/O modules.
Comparison: cable requirements and wiring costs for integrating I/O modules.
Comparison: resources required by different automation solutions to integrate I/O modules.

In two minutes

ASi installation also delivers substantial savings compared with conventional parallel wiring. Wiring a single motor starter with thirteen wires can easily take sixty to ninety minutes, whereas the same job can be done in two minutes with ASi, using an active distributor with an M12 connection to the motor and a two-core profile cable already installed in the system.  

Finally, Bihl+Wiedemann's ASi solutions also stand out for their economically attractive module prices and low cost per signal collected. Depending on individual requirements, a broad portfolio of ASi modules is available, with two to sixteen I/Os or one to eight IO-Link master ports. It is no wonder that wiring costs with ASi can be up to 70 per cent lower than with other fieldbus systems. 

Have a business enquiry for Bihl+Wiedemann GmbH? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectControl & network
  • CompanyBihl+Wiedemann GmbH
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.