Safety muting: greater safety, lower costs
Text Thomas Rönitzsch, Bihl+WiedemannImage Bihl+Wiedemann

Muting means that the protective function of a non-contact safety device, such as a light curtain, is temporarily disabled under controlled conditions. It is widely used in automated machinery and systems such as robot cells, lift table stations, and strapping and labelling machines. Muting enables automatic material transport through areas that would normally be inaccessible, for example inside safety fences. This is essential for protecting operators, maintenance staff and unauthorised personnel from moving machinery and other hazards.

The ASi-5 Safety Muting Module BWU4411 enables muting applications and machine guarding up to SIL3 and PLe. Bihl+Wiedemann developed this IP67-rated module to support both safe single-channel and dual-channel muting signals and, depending on the configuration, provide up to eight standard inputs or outputs. The module is suitable for all common muting methods, including cross muting, where both sensors must signal simultaneously to start the muting cycle, and various types of sequential four-beam muting. In this method, sensors must signal in a specific order to activate muting.
The module also collects signals from all connected standard sensors and integrates components such as reset buttons and muting lamps into the application. This makes it the central hub for all muting components and their input and output signals. This functionality requires just one ASi-5 address, significantly reducing hardware and addressing costs. The ASi-5 Safety Muting Module also has an integrated power supply connection for non-contact safety devices.

Cost-effective solution
During operation, the BWU4411 provides users with valuable diagnostic data via Bihl+Wiedemann’s ASi-5/ASi-3 gateways, with optional connections through to the IIoT. The muting function can be configured automatically in Bihl+Wiedemann’s ASIMON360 safety software. Signals can also be sent to a safety controller for further processing via a safe protocol such as PROFIsafe, CIP Safety or FSoE.
With ASi-5 Safety, muting can be implemented safely and easily using a single piece of hardware, thanks to user-friendly AS-Interface wiring with piercing technology. The module is also more than 60% cheaper than comparable Ethernet solutions, making it a highly cost-effective choice.

Maximum ease of use with AS-Interface
Solutions based on AS-Interface and ASi Safety, including ASi-5 and ASi-5 Safety, offer not only efficiency but also simplicity and flexibility. With gateways available for many fieldbuses, an existing solution can easily be adapted to new requirements, such as a different controller for a project. In that case, only the gateway needs to be replaced.
Identical muting applications within an installation can be copied easily and configured, controlled and diagnosed in the event of faults under a single IP address. If a module fails, the entire configuration can be copied automatically to a replacement module, minimising downtime. Safety devices and complex standard modules, such as the IO-Link master, can both be integrated on the same ASi cable. This allows you to continue benefiting from the advantages of ASi and ASi Safety. AS-Interface therefore offers the optimal solution for every application.