Control & network

Preventing electromagnetic interference

Text LAPP, Evi HussonImage LAPP

ÖLFLEX® SERVO FD zeroCM: nieuw kabelontwerp met innovatieve zeroCM®-technologie voorkomt elektromagnetische interferentie.
ÖLFLEX® SERVO FD zeroCM: nieuw kabelontwerp met innovatieve zeroCM®-technologie voorkomt elektromagnetische interferentie.

Digitalisation and automation are making factories increasingly smart. This also means that large amounts of electrical energy and data are often transmitted in a confined space. As a result, the risk of electromagnetic interference is increasing. Even a single poorly shielded connector can bring an entire production line to a halt. The solution? Electromagnetically compatible (EMC) components.

“Electromagnetic compatibility means that components and systems, often electrical and electronic, must continue to function properly in an electromagnetic environment without themselves causing electromagnetic interference that is unacceptable to other components or systems in that environment,” explains Alexandru Custura, Product Manager at LAPP. “A device must therefore neither cause interference nor be susceptible to electromagnetic interference from its surroundings.”

Unique 360° shielding, achieved by semi-automatically attaching the connector to the cable shielding on LAPP servo cables.

How EMC works

As the problem of electromagnetic interference grows, the global market for EMC solutions is growing by seven per cent a year. “Any electromagnetic interference can always be traced back to a source of interference. This could be a high-current device, such as a frequency-controlled motor, or a cable. The source of interference corresponds to an affected device, the receiver, such as a sensor or data network cable. The coupling mechanism causes the interference.”

LAPP’s EPIC® EMC connectors provide 360° shielding and a vibration-resistant shielding connection.

Types of coupling

“There are four types of coupling,” Custura continues. The first is galvanic, or conductive, coupling. In this case, the source and receiver of interference are connected, for example via a common earth conductor. An interference current flowing through the common earth conductor causes the problem. The second type is radiative coupling. This usually occurs when the source and receiver of interference are far apart. The conductors effectively act as antennas, resulting in electromagnetic interference.”

Capacitive coupling is the third type. “Here, there is little space between the source and receiver of interference, but they are not physically connected. The interference is caused by the electric field present. Finally, there is inductive coupling. Here too, there is little space between the source and receiver of interference, and they are not connected. The interference is caused by the magnetic field present.” In practice, several types of coupling often occur in the same situation. The key is to suppress them, for example by using shielded cables.

Shield the entire cable surface

“To ensure good EMC, you need to start with good earthing,” says Custura. “This is crucial for EMC. Shielding has no effect without good earthing. Data cables must therefore always be earthed at both ends. During installation, it is important that the shielding completely covers the cable surface and is placed all the way round inside a connector housing at both ends of the cable. To take care of everything for customers, LAPP offers the Ölflex Connect programme. This includes ready-assembled cable systems, with or without a cable drag chain, which are fully tested and supplied to the required length.”

LAPP also offers a wider range of power and control cables, including cables with tinned copper braiding, copper wire wrapping or aluminium-laminated plastic foil. “There is a solution for every application.”

Connectors

EMC connectors are important too, alongside cables. “Our EMC connectors provide 360-degree shielding and a vibration-resistant connection. Combined with our Skintop Brush cable glands, they are easy to install and deliver maximum EMC.” EMC cable glands are often already integrated into LAPP connector systems. “They make it possible to connect a protective conduit and bring the cable shielding into contact with the functional earth or PE contact of the connector system.” Custura also highlights LAPP’s zeroCM technology. This patented cable design provides 100% electrical symmetry. It significantly improves EMC.”

A good understanding

Companies are integrating increasing numbers of electrical and electronic components, raising the risk of interference. “A good understanding of the system and choosing the right components are essential to suppress electromagnetic interference. We offer integrated solutions in cable and connectivity technology, and have the expertise in-house to provide companies with solutions that prevent interference.” 

Een zakelijke vraag aan Lapp Benelux B.V.? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectControl & network
  • CompanyLapp Benelux B.V.
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.