Moxa develops and supplies robust industrial networking solutions tailored to a wide range of often demanding applications. For example, its EDS-4000 Series managed switches are used for DCS integration. These PROFINET CC-B-compatible Ethernet switches ensure seamless interoperability with other PROFINET devices in oil refineries. The SDS-G3016 smart switches, also PROFINET CC-B-compatible, combine a robust design with a wide operating temperature range and high EMC resistance to ensure reliable operation in the extreme conditions of the automotive industry.

Oil refineries play a crucial role in converting crude oil into valuable petroleum products such as petrol, diesel and various chemicals. The processes involved often take place at high temperatures and pressures and involve hazardous substances. Downtime can lead to significant safety risks, environmental problems and financial losses. As a result, these processes are often technologically advanced and designed with safety in mind to ensure production efficiency. A DCS (Distributed Control System or Digital Control System) is essential for engineers to monitor industrial processes continuously. This helps prevent costly downtime, improve safety and optimise productivity. Reliable connectivity, real-time monitoring and failover mechanisms are essential for consistent operation in oil refineries.

Schematic of a network installation in an oil refinery, showing the integration of EDS-4012 managed switches.

“Moxa’s EDS-4000 Series industrial managed switches are specially designed for demanding applications such as these. These PROFINET CC-B-compatible Ethernet switches ensure seamless interoperability with other PROFINET devices, including controllers and I/O equipment. They also enable precise, low-latency data transfer for seamless coordination between the DCS, remote I/Os and field devices, making efficient, synchronised process control possible,” explains Karel Mus of Technolec. “These managed switches also support the Media Redundancy Protocol (MRP) for fault-tolerant network redundancy. This mechanism enables seamless failover in the event of a fault, helping to prevent costly downtime. The EDS-4000 Series meets UL Class I Division 2 and ATEX certification requirements, making it safe and reliable to use in the extreme conditions found in refineries.” 

Diagram of an automotive network solution using SDS-G3016 smart switches and EDS-G2005-ELP unmanaged switches.

Building reliable networks for automotive manufacturers

A consistently high output is impossible without high efficiency and uptime. This applies to every production environment, including the automotive industry. Synchronous, real-time communication plays a crucial role in ensuring uninterrupted operation. Any sudden stoppage interrupts assembly lines, slows production and therefore reduces output. PROFINET is one of the most widely used protocols for integrating and managing these systems in real time. Robust devices are also essential for ensuring stable connectivity in automotive factories, where extreme temperatures, vibration and EMI are common. This is why integrators repeatedly choose robust solutions for such demanding applications, including switches that support PROFINET and can be monitored using existing SCADA and HMI systems. The equipment must also be easy to install in small, crowded control cabinets.

Moxa’s EDS-4000 Series industrial managed switches are specially designed for demanding applications such as DCS integration in oil refineries.

“Moxa’s networking solutions combine a robust design with a wide operating temperature range and high EMC resistance, ensuring reliable operation in the extreme conditions found at automotive manufacturers. For example, Moxa’s SDS-G3016 smart switches are PROFINET CC-B-compatible and feature simple PROFINET profile configuration via a rotary DIP switch or web interface. This enables engineers to monitor network status through existing SCADA or HMI systems, so they can respond quickly to events and minimise any downtime. The SDS-G3016 Series also supports MRP network redundancy to ensure that critical control networks keep running without interruption,” says Mus. “For the subsystem network, Moxa’s PROFINET CC-A-compatible EDS-G2005-EL Series unmanaged switches use QoS to prioritise PROFINET packets and maximise operational performance. The ultra-compact design and full gigabit­bandwidth of both the SDS-G3016 and EDS-G2005-EL Series make installation in confined spaces easy and enable the seamless transfer of large volumes of production data.” 

Een zakelijke vraag aan Technolec? Get in touch

Companies in this story

Keep following this