Control & network

CC Nederland introduces the Bernstein SCR-P Safety Controller with DCD diagnostics

CC Nederland introduces the Bernstein SCR-P Safety Controller with DCD diagnostics

The Bernstein Safety Controller in the SCR P series is a programmable safety relay particularly suited to larger machines with multiple safety components or SRF safety sensors. This programmable safety controller lets you bring in multiple signals from safety sensors or components. These signals can be configured and programmed quickly using drag & drop with the Bernstein SCR-P software. All Daisy Chain Diagnostics (DCD) information and diagnostic data are available wherever and however you need them. In short, it is a smart solution offering comprehensive diagnostic data for your safety application.

Read on to find out why the Safety Controller is unique within Bernstein’s Safety System, what its main benefits are and why DCD diagnostics matter for your machines.

Flexibility in the safety circuit

With a standard safety relay, for example, the entire machine is switched off when an emergency stop is pressed. What makes the Safety Controller unique is that different zones can be switched off independently. This provides flexibility when designing the safety circuit and determining how the machine is shut down. In addition, its straightforward drag & drop configuration and programming, together with the ability to communicate with another PLC system, make it a unique product in our range of safety relays. The SCR-P Safety Controller comes as standard with communication options for SIEMENS Profinet, Ethernet/IP and Modbus.

What are the main benefits?

The Bernstein SCR-P Safety Controller is the latest addition to Bernstein’s Smart Safety System and a smart alternative to standard SCR safety relays. Read on to find out all about the controller’s benefits.

Two-wire system

The Safety Controller uses a two-wire system. Two conductors run along the shutdown components in a cable, while also transmitting diagnostic data over the same cable. This data can show, for example, whether a door has opened or a hectometre is misaligned. The two-wire system runs over the existing OSSD signals in the safety circuit.

Simple wiring

Normally, each switch is wired individually to a control cabinet. With the Safety Controller, all cables can be daisy-chained, significantly reducing the amount of wiring required. This cuts costs and installation time. More cabling also increases the risk of faults, so that risk is reduced too. Daisy-chaining OSSD safety signals is nothing new in itself, but what makes this system unique is that all status messages are also transmitted over the same wires. This makes it easy to see which safety switch has been interrupted among the sensors connected in series.

Flexibility when expanding a machine

When equipment is added to a machine, the safety chain must be extended with additional safety sensors. With the Safety Controller, there is no need to buy a new safety relay. You only need to configure the extension in the software, without making any changes to the control cabinet.

Why DCD diagnostics matter for your machines

In addition to the benefits outlined above, the safety chain can also read the status of individual SRF sensors. The sensor furthest from the control system, up to 100 metres away, generates a data packet containing its status information and modulates it onto the safety signals. The next sensor reads the packet, adds its own status information and passes it on to the next sensor. At the control end of the safety chain, an additional diagnostic module separates the diagnostic information from the safety signal and prepares it for transmission to a higher-level system, such as a PLC system. Because there is no need to search for the cause of a machine shutdown, as it is immediately visible, machine downtime is reduced, among other benefits.

De video laadt pas als je op afspelen klikt.

Direct connection to a PLC system

The Safety Controller has a direct connection to PLC systems via Profinet, Ethernet/IP or Modbus. There are 4 steps to complete the PLC connection.

  • Ensure the configuration is safe.
  • Run an automatic interface configuration.
  • Integrate the SCR-P Safety Controller into the PLC hardware configuration using the user manual.
  • All information and diagnostic data are now available in the PLC system.

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeSafe and resilient installations
  • SubjectControl & network
Share this article

Follow Industrial Automation Vlaanderen

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.