TwinCAT Controller Redundancy protège le temps de fonctionnement de l’installation grâce à un fonctionnement redondant de commande à l’aide de composants standard.
TwinCAT Controller Redundancy protège le temps de fonctionnement de l’installation grâce à un fonctionnement redondant de commande à l’aide de composants standard.

 The software solution protects plant uptime through controller redundancy

Plant availability plays a crucial role, particularly in the process industry. Integrating redundancy into the design of automation technology is therefore essential. That is why Beckhoff has expanded its extensive range of solutions in this area to include a software solution for redundant control: TwinCAT Controller Redundancy. 

While the robust design of the company’s industrial PCs already ensures a high level of availability, Beckhoff is expanding its product portfolio with TwinCAT Controller Redundancy (TF1100). This software solution enables two standard industrial PCs, both running the same PLC program, to operate as redundant controllers in just a few simple steps. 

An additional, high-performance network connection between the two controllers provides the required synchronisation. Standard Ethernet is used, so no dedicated hardware components are required. With minimal effort, this ensures that only one of the two industrial PCs communicates with the fieldbus components at any given time, while the control programs run simultaneously on both computers. This synchronisation is essential to allow the primary industrial PC to be switched over in the event of a failure without losing any information. 

Other redundancy methods 

In addition to controller redundancy, the proven EtherCAT Redundancy software (TF6220) protects against failures caused by faulty cable connections. The I/O modules are connected using two separate cables, which should ideally be routed through different locations. While EtherCAT Redundancy covers communication between the controller and the fieldbus, TwinCAT Parallel Redundancy Protocol (PRP, TF6230) now also provides cable redundancy for Ethernet communication in accordance with IEC 62439-3 with higher-level systems such as MES or decoupled HMI systems. The protocol defines a transparent, redundant network connection that can be monitored and diagnosed in TwinCAT. 

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeReliable and open industrial networks
  • SubjectSoftware, IT, OT & cybersecurity
Share this article

Follow on Industrial Automation Wallonie

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.