Digitalisation and automation are making factories smarter. However, transferring high electrical power and data in a confined space increases the risk of electromagnetic interference. A poorly shielded connector can bring production to a standstill. The solution is to use components that are electromagnetically compatible (EMC). 

,“Electromagnetic compatibility means that components and systems, often electrical and electronic, must be able to continue operating in an electromagnetic environment without causing unacceptable interference to other components or systems in that environment,” explains Alexandru Custura, Product Manager at LAPP. 

How EMC works

The issue of electromagnetic interference is growing, and the number of EMC solutions worldwide increases by seven per cent every year. “Electromagnetic interference comes from a source. This could be equipment carrying a high current, such as a variable-frequency drive or a cable. The source of interference interacts with a piece of equipment, the receiver, such as a sensor or a data cable. The coupling mechanism is what causes the interference.” 

The patented concept behind ÖLFLEX® SERVO FD zeroCM® technology prevents electromagnetic interference.

Types of coupling

“There are four types of coupling,” continues Alexandru Custura. There is galvanic or conductive coupling, where the source and receiver of interference are connected to each other, for example by a shared protective earth conductor. Interference current carried by the shared protective earth conductor causes disruption. Then there is radiative coupling, which generally occurs when the source and receiver of interference are some distance apart. The conductors act as antennas, causing electromagnetic interference.” 

Capacitive coupling is a third type. “There is little space between the source and receiver of interference, but they are not physically connected. The disturbance is caused by the electric field present. Finally, there is inductive coupling. Here, too, there is little space between the source and receiver of interference, but they are not connected. The disturbance is caused by the magnetic field present.” In practice, there is usually a combination of coupling types, which needs to be optimised, for example by using shielded cables. 

Fully shielded cable surface

“To ensure good EMC, proper earthing is essential, otherwise the shielding has no effect,” continues Alexandru Custura. “Data cables must be earthed at both ends. During assembly, the shield must cover the entire cable surface and be positioned around the connector housing and at both ends of the cable. LAPP offers its Ölflex Connect range: ready-to-use, pre-assembled cable systems, with or without cable carriers, tested and available in the required length.”

LAPP also offers other power and control cables, including tinned copper braids, coated copper wire and aluminium-plastic laminated foil. “We have a solution for every application.”

LAPP’s EPIC® EMC connectors provide 360° shielding and a vibration-resistant shield connection.

Connectors

Alongside cables, EMC connectors are also important. “Our EMC connectors provide 360° shielding and a vibration-resistant shield connection. Combined with our Skintop Brush cable glands, they ensure easy assembly and maximum EMC.” EMC cable glands are generally already integrated into LAPP connector systems. “They allow a protective conduit to be connected, with the cable shield in contact with the connector system’s PE element.” Alexandru Custura also mentions LAPP’s zeroCM technology, a patented cable concept offering 100% electrical symmetry, which significantly improves EMC.”

A sound understanding

Companies are incorporating more electrical and electronic components, increasing the risk of interference. “A sound understanding of the system and the selection of the right components are essential to eliminate electromagnetic interference. We offer integrated solutions and have the knowledge and expertise to implement solutions that prevent electromagnetic interference.” 

Een zakelijke vraag aan Lapp Benelux B.V.? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeData-driven design and operations
  • SubjectServices & solutions
  • CompanyLapp Benelux B.V.
Share this article

Follow on Industrial Automation Wallonie

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.